Wasp WLS9500 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Digitalizar e Imprimir Wasp WLS9500. Wasp WLS9500 User manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Wasp WLS 9500

USER MANUALWasp WLS 9500www.waspbarcode.com

Página 2

WLS 9500 Product Reference Guidex

Página 3 - Product Reference Guide

WLS 9500 Product Reference Guide7-12Decode UPC/EAN/JAN Supplementals (continued)Decode UPC/EAN/JAN Only With Supplementals*Ignore SupplementalsAutodis

Página 4

Symbologies 7-13UPC/EAN/JAN Supplemental RedundancyWith Autodiscriminate UPC/EAN/JAN Supplementals selected, this option adjusts the number of times a

Página 5 - Contents

WLS 9500 Product Reference Guide7-14Transmit UPC-E Check DigitThe check digit is the last character of the symbol used to verify the integrity of the

Página 6

Symbologies 7-15Transmit UPC-E1 Check DigitThe check digit is the last character of the symbol used to verify the integrity of the data. Scan the appr

Página 7 - Symbologies

WLS 9500 Product Reference Guide7-16UPC-E PreamblePreamble characters are part of the UPC symbol consisting of Country Code and System Character. Thre

Página 8

Symbologies 7-17UPC-E1 PreamblePreamble characters are part of the UPC symbol consisting of Country Code and System Character. Three options are given

Página 9 - Contents ix

WLS 9500 Product Reference Guide7-18Convert UPC-E1 to UPC-AEnable this to convert UPC-E1 decoded data to UPC-A format before transmission. After conve

Página 10

Symbologies 7-19UCC Coupon Extended CodeWhen enabled, this parameter decodes UPCA bar codes starting with digit ‘5’, EAN-13 bar codes starting with di

Página 11 - About This Guide

WLS 9500 Product Reference Guide7-20Code 128Enable/Disable Code 128To enable or disable Code 128, scan the appropriate bar code below.Enable/Disable U

Página 12

Symbologies 7-21Enable/Disable ISBT 128ISBT 128 is a variant of Code 128 used in the blood bank industry. Scan the appropriate bar code below to enabl

Página 13 - Service Information

About This GuideIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 14

WLS 9500 Product Reference Guide7-22Code 39Enable/Disable Code 39To enable or disable Code 39, scan the appropriate bar code below.Enable/Disable Trio

Página 15 - Getting Started

Symbologies 7-23Convert Code 39 to Code 32Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry. Scan the appropriate bar code b

Página 16

WLS 9500 Product Reference Guide7-24Set Lengths for Code 39he length of a code refers to the number of characters (i.e., human readable characters), i

Página 17 - Unpacking

Symbologies 7-25• Any Length - Select this option to decode Code 39 symbols containing any number of characters within the scanner capability.Code 39

Página 18 - Setting Up the Scanner

WLS 9500 Product Reference Guide7-26Transmit Code 39 Check DigitScan the appropriate bar code below to transmit Code 39 data with or without the check

Página 19 - Scanning

Symbologies 7-27Code 39 Full ASCII ConversionCode 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set.

Página 20

WLS 9500 Product Reference Guide7-28This feature affects Code 39 only. If selecting Buffer Code 39, we recommend configuring the scanner to decode Cod

Página 21

Symbologies 7-29Clear Transmission BufferTo clear the transmission buffer, scan the Clear Buffer bar code below, which contains only a start character

Página 22 - LED Definitions

WLS 9500 Product Reference Guide7-30Overfilling Transmission BufferThe Code 39 buffer holds 200 characters. If the symbol just read results in an over

Página 23 - Scanning in Hand-Held Mode

Symbologies 7-31Code 93Enable/Disable Code 93To enable or disable Code 93, scan the appropriate bar code below.Set Lengths for Code 93The length of a

Página 24

WLS 9500 Product Reference Guidexii

Página 25 - Scanning 2-7

WLS 9500 Product Reference Guide7-32Set Lengths for Code 93 (continued)Code 93 - One Discrete LengthCode 93 - Two Discrete LengthsCode 93 - Length Wit

Página 26 - Scanning in Hands-Free Mode

Symbologies 7-33Code 11Code 11To enable or disable Code 11, scan the appropriate bar code below.Set Lengths for Code 11The length of a code refers to

Página 27 - Angle Adjustment

WLS 9500 Product Reference Guide7-34Set Lengths for Code 11 (continued)Code 11 - One Discrete LengthCode 11 - Two Discrete LengthsCode 11 - Length Wit

Página 28 - Decode Zone

Symbologies 7-35Code 11 Check Digit VerificationThis feature allows the scanner to check the integrity of all Code 11 symbols to verify that the data

Página 29 - Maintenance, Troubleshooting

WLS 9500 Product Reference Guide7-36Interleaved 2 of 5 (ITF)Enable/Disable Interleaved 2 of 5To enable or disable Interleaved 2 of 5, scan the appropr

Página 30

Symbologies 7-37Set Lengths for Interleaved 2 of 5 (continued)I 2 of 5 Check Digit VerificationWhen this feature is enabled, the scanner checks the in

Página 31 - Troubleshooting

WLS 9500 Product Reference Guide7-38Transmit I 2 of 5 Check DigitScan the appropriate bar code below to transmit I 2 of 5 data with or without the che

Página 32

Symbologies 7-39Discrete 2 of 5 (DTF)Enable/Disable Discrete 2 of 5To enable or disable Discrete 2 of 5, scan the appropriate bar code below.Set Lengt

Página 33

WLS 9500 Product Reference Guide7-40Set Lengths for Discrete 2 of 5 (continued)D 2 of 5 - One Discrete LengthD 2 of 5 - Two Discrete LengthsD 2 of 5 -

Página 34 - Technical Specifications

Symbologies 7-41Chinese 2 of 5Enable/Disable Chinese 2 of 5To enable or disable Chinese 2 of 5, scan the appropriate bar code below.Enable Chinese 2 o

Página 35

xiiiIntroductionThe WLS 9500 Product Reference Guide provides general instructions for setting up, operating, maintaining, and troubleshooting the WLS

Página 36

WLS 9500 Product Reference Guide7-42Codabar (NW - 7)Enable/Disable CodabarTo enable or disable Codabar, scan the appropriate bar code below.Set Length

Página 37 - User Preferences

Symbologies 7-43Set Lengths for Codabar (continued).CLSI EditingWhen enabled, this parameter strips the start and stop characters and inserts a space

Página 38

WLS 9500 Product Reference Guide7-44NOTIS EditingWhen enabled, this parameter strips the start and stop characters from a decoded Codabar symbol. Enab

Página 39

Symbologies 7-45MSIEnable/Disable MSITo enable or disable MSI, scan the appropriate bar code below.Set Lengths for MSIThe length of a code refers to t

Página 40

WLS 9500 Product Reference Guide7-46Set Lengths for MSI (continued)MSI Check DigitsWith MSI symbols, one check digit is mandatory and always verified

Página 41

Symbologies 7-47Transmit MSI Check Digit(s)Scan the appropriate bar code below to transmit MSI data with or without the check digit.MSI Check Digit Al

Página 42 - *High Volume

WLS 9500 Product Reference Guide7-48RSS (Reduced Space Symbology)The variants of RSS are RSS 14, RSS Expanded and RSS Limited. RSS 14 and RSS Expanded

Página 43 - *Multi-line Always Raster

Symbologies 7-49Convert RSS to UPC/EANThis parameter only applies to RSS-14 and RSS Limited symbols not decoded as part of a Composite symbol. Enable

Página 44 - *Full Width

WLS 9500 Product Reference Guide7-50Symbology - Specific Security LevelsRedundancy LevelThe scanner offers four levels of decode redundancy. Select hi

Página 45 - *Beep After Good Decode

Symbologies 7-51Redundancy Level (continued)*Redundancy Level 1Redundancy Level 2Redundancy Level 3Redundancy Level 4

Página 46

WLS 9500 Product Reference Guidexiv

Página 47 - Keyboard Wedge Interface

WLS 9500 Product Reference Guide7-52Security LevelThe scanner offers four levels of decode security for delta bar codes, which include the Code 128 fa

Página 48

Symbologies 7-53Bi-directional RedundancyEnable Bi-directional Redundancy to add security to linear code type security levels. When enabled, a bar cod

Página 49

WLS 9500 Product Reference Guide7-54Symbology - Intercharacter GapThe Code 39 and Codabar symbologies have an intercharacter gap that is customarily q

Página 50

8Miscellaneous Scanner OptionsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 51 - Keyboard Wedge Host Types

WLS 9500 Product Reference Guide8-2

Página 52 - *North American

Miscellaneous Scanner Options 8-3IntroductionThis chapter includes commonly used bar codes to customize how data is transmitted to the host device. Th

Página 53 - Ignore Unknown Characters

WLS 9500 Product Reference Guide8-4Miscellaneous Parameter DefaultsTable 8-1 lists the defaults for miscellaneous scanner options parameters. If you w

Página 54 - *No Delay

Miscellaneous Scanner Options 8-5Miscellaneous Scanner ParametersTransmit Code ID CharacterA Code ID character identifies the code type of a scanned b

Página 55

WLS 9500 Product Reference Guide8-6Prefix/Suffix Values (continued)Scan Data Transmission FormatTo change the scan data format, scan Scan Options and

Página 56 - *Disable Function Key Mapping

Miscellaneous Scanner Options 8-7Scan Data Transmission Format (continued)Scan Options*Data As Is<DATA> <SUFFIX><PREFIX> <DATA>

Página 57 - Send Make and Break

1Getting StartedIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 58 - Keyboard Maps

WLS 9500 Product Reference Guide8-8FN1 Substitution ValuesThe Wedge and USB HID Keyboard hosts support an FN1 substitution feature. When enabled any F

Página 59

Miscellaneous Scanner Options 8-9

Página 60

WLS 9500 Product Reference Guide8-10

Página 61

AStandard Default ParametersTable A-1. Standard Default Parameters TableParameter Default Page NumberUser PreferencesSet Default Parameter Restore De

Página 62

WLS 9500 Product Reference GuideA-2Country Types (Country Codes) North American 5-3Ignore Unknown Characters Send 5-3Keystroke Delay No Delay 5-8Intra

Página 63

Standard Default Parameters A-3EAN-13/JAN 13 Enable 7-10Bookland EAN Disable 7-11Decode UPC/EAN/JAN Supplementals (2 and 5 digits) Ignore 7-12Decode U

Página 64

WLS 9500 Product Reference GuideA-4Buffer Code 39 Disable 7-28Code 93Code 93 Disable 7-31Set Length(s) for Code 93 4 to 55 7-31Code 11Code 11 Disable

Página 65

Standard Default Parameters A-5Set Length(s) for MSI 2 to 55 7-45MSI Check Digits One 7-46Transmit MSI Check Digit Disable 7-47MSI Check Digit Algorit

Página 66

WLS 9500 Product Reference GuideA-6

Página 67 - Extended Keypad Keystroke

BSample Bar CodesCode 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 68

WLS 9500 Product Reference Guide1-2

Página 69 - USB Interface

WLS 9500 Product Reference GuideB-2

Página 70

Sample Bar Codes B-3Code 39UPC/EANUPC-A, 100%EAN-13, 100%Code 128123ABC012345678905345678901234012345678901234567890123456789012345678901234

Página 71 - Connecting a USB Interface

WLS 9500 Product Reference GuideB-4Interleaved 2 of 5RSSRSS variants must be enabled to read the bar codes below (see RSS (Reduced Space Symbology) on

Página 72 - USB Parameter Defaults

Sample Bar Codes B-5RSS-1455432198673467(RSS-14 Truncated)90876523412674(RSS-14 Stacked)78123465709811(RSS-14 Stacked Omni-Directional)

Página 73 - USB Host Parameters

WLS 9500 Product Reference GuideB-6

Página 74

CNumeric Bar CodesNumeric Bar Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 75

WLS 9500 Product Reference GuideC-2

Página 76 - USB CAPS Lock Override

Numeric Bar Codes C-3Numeric Bar CodesFor parameters requiring specific numeric values, scan the appropriately numbered bar code(s).012345

Página 77 - Emulate Keypad

WLS 9500 Product Reference GuideC-4Numeric Bar CodesFor parameters requiring specific numeric values, scan the appropriately numbered bar code(s).Canc

Página 78 - *Disable FN1 Substitution

DASCII Character SetsTable D-1. ASCII Value Standard Default Parameters TableASCII ValueFull ASCIICode 39 Encode Character Keystroke1000 %U CTRL 2100

Página 79 - Convert Case

Getting Started 1-3IntroductionThe scanner combines excellent scanning performance and advanced ergonomics to provide the best value in a lightweight

Página 80 - ASCII Character Set for USB

WLS 9500 Product Reference GuideD-21012 $L CTRL L1013 $M CTRL M/ENTER11014 $N CTRL N1015 $O CTRL O1016 $P CTRL P1017 $Q CTRL Q1018 $R CTRL R1019 $S CT

Página 81

ASCII Character Sets D-31040 /H (1041 /I )1042 /J *1043 /K +1044 /L ,1045 - -1046 . .1047 /o /1048 0 01049 1 11050 2 21051 3 31052 4 41053 5 51054 6 6

Página 82

WLS 9500 Product Reference GuideD-41068 D D1069 E E1070 F F1071 G G1072 H H1073 I I1074 J J1075 K K1076 L L1077 M M1078 N N1079 O O1080 P P1081 Q Q108

Página 83

ASCII Character Sets D-51096 %W ‘1097 +A a1098 +B b1099 +C c1100 +D d1101 +E e1102 +F f1103 +G g1104 +H h1105 +I i1106 +J j1107 +K k1108 +L l1109 +M m

Página 84

WLS 9500 Product Reference GuideD-61124 %Q I1125 %R }1126 %S ~The keystroke in bold is sent only if the “Function Key Mapping” is enabled. Otherwise,

Página 85

ASCII Character Sets D-72089 ALT Y2090 ALT ZTable D-3. Misc. Key Standard Default TableMisc. Key Keystroke3001 PA 13002 PA 23003 CMD 13004 CMD 23005 C

Página 86

WLS 9500 Product Reference GuideD-83056 GUI 83057 GUI 93065 GUI A3066 GUI B3067 GUI C3068 GUI D3069 GUI E3070 GUI F3071 GUI G3072 GUI H3073 GUI I3074

Página 87

ASCII Character Sets D-94005 PF 54006 PF 64007 PF 74008 PF 84009 PF 94010 PF 104011 PF 114012 PF 124013 PF 134014 PF 144015 PF 154016 PF 16Table D-6.

Página 88

WLS 9500 Product Reference GuideD-105020 F 205021 F 215022 F 225023 F 235024 F 24Table D-7. Numeric Key Standard Default TableNumeric Keypad Keystroke

Página 89

ASCII Character Sets D-117005 Pg Dn7006 Pause7007 Scroll Lock7008 Backspace7009 Tab7010 Print Screen7011 Insert7012 Home7013 Enter7014 Escape7015 Up A

Página 90

WLS 9500 Product Reference Guide1-4Setting Up the ScannerInstalling the Interface CableTo connect the interface cable:1. Insert the interface cable’s

Página 91 - Symbologies 7-3

WLS 9500 Product Reference GuideD-12

Página 92

EProgramming ReferenceSymbol Code Identifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 93

WLS 9500 Product Reference GuideE-2

Página 94 - Symbology Parameter Defaults

Programming Reference E-3Symbol Code IdentifiersTable E-1. Symbol Code CharactersCode Character Code TypeA UPC/EANB Code 39, Code 39 Full ASCII, Code

Página 95

WLS 9500 Product Reference GuideE-4AIM Code IdentifiersEach AIM Code Identifier contains the three-character string ]cm where:] = Flag Character (ASCI

Página 96

Programming Reference E-5Code 128 0 Standard data packet, no Function code 1 in first symbol position.1 Function code 1 in first symbol character posi

Página 97 - *Enable UPC-E

WLS 9500 Product Reference GuideE-6

Página 98 - *Enable EAN-8

Aaiming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5ASCII valueskeyboard wedge . . . . . . . . . . . . . . . . . . 5-13standar

Página 99 - *Disable Bookland EAN

WLS 9500 Product Reference GuideIN-2code 39 transmit check digit . . . . 7-26code 39, enable/disable . . . . . . . . 7-22code 93 lengths . . .

Página 100 - *Ignore Supplementals

Index IN-3Nnotational conventions . . . . . . . . . . . . . . . . . 2-xiiiNW - 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-42Ppar

Página 101 - *Transmit UPC-A Check Digit

2ScanningIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 103 - *Transmit UPC-E1 Check Digit

WLS 9500 Product Reference Guide2-2

Página 104 - UPC-E Preamble

Scanning 2-3IntroductionThis chapter provides beeper and LED definitions, techniques involved in scanning bar codes, general instructions and tips abo

Página 105 - Convert UPC-E to UPC-A

WLS 9500 Product Reference Guide2-4Beeper DefinitionsThe scanner issues different beep sequences and patterns to indicate status. Table 2-1 defines be

Página 106 - *Disable EAN/JAN Zero Extend

Scanning 2-5Scanning in Hand-Held ModeInstall and program the scanner (see Setting Up the Scanner on page 1-4). For assistance, contact the local supp

Página 107 - UCC Coupon Extended Code

WLS 9500 Product Reference Guide2-6When scanning using a multi-line scan mode, at least one scan line must cross every bar and space of the symbol.Fig

Página 108 - Code 128

Scanning 2-7The scanner can be tilted up to 65° forward or back and achieve a successful decode (Figure 2-5). Simple practice quickly shows what toler

Página 109 - *Enable ISBT 128

WLS 9500 Product Reference Guide2-8Scanning in Hands-Free ModeThe optional Intellistand adds greater flexibility to scanning operation. When the scann

Página 110 - *Disable Trioptic Code 39

Scanning 2-9Scanning with the WLS 9500 Hands Free StandWhen the scanner is placed in the Intellistand, the scan pattern selected in hand-held triggere

Página 111 - *Disable Code 32 Prefix

WLS 9500 Product Reference Guide2-10Decode ZoneFigure 2-8. WLS 9500 Decode ZoneNote: Typical performance at 73° F (23° C) on high quality

Página 112 - Set Lengths for Code 39

3Maintenance, Troubleshooting& Technical SpecificationsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 113 - *Disable Code 39 Check Digit

WLS 9500Product Reference GuideApril 2006

Página 114 - Transmit Code 39 Check Digit

WLS 9500 Product Reference Guide3-2

Página 115 - *Disable Code 39 Full ASCII

Maintenance, Troubleshooting& Technical Specifications3-3IntroductionThis chapter provides suggested scanner maintenance, troubleshooting, technic

Página 116 - *Do Not Buffer Code 39

WLS 9500 Product Reference Guide3-4The scan line is not crossing every bar and space of the symbol.Move the symbol until the scan line is within the a

Página 117 - Transmit Buffer

Maintenance, Troubleshooting& Technical Specifications3-5If after performing these checks the symbol still does not scan, contact the distributor

Página 118

WLS 9500 Product Reference Guide3-6Technical SpecificationsTable 3-2. Technical SpecificationsItem DescriptionPhysical CharacteristicsDimensions: 6.7

Página 119 - *Disable Code 93

Maintenance, Troubleshooting& Technical Specifications3-7ESD 15 kV air discharge8 kV indirect dischargeRegulatoryElectrical Safety UL1950, CSA C22

Página 120 - Code 93 - Any Length

WLS 9500 Product Reference Guide3-8

Página 121 - *Disable Code 11

4User PreferencesIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 122 - Code 11 - Any Length

WLS 9500 Product Reference Guide4-2

Página 123 - *Disable

User Preferences 4-3IntroductionIf desired, program the scanner to perform various functions, or activate different features. This chapter describes e

Página 124 - Interleaved 2 of 5 (ITF)

© 2006 by Wasp Technologies. All rights reserved.No part of this publication may be reproduced or used in any form, or by any electrical or mechanical

Página 125

WLS 9500 Product Reference Guide4-4User Preferences Parameter DefaultsTable 4-1 lists the defaults for user preferences parameters. To change any opti

Página 126 - Convert I 2 of 5 to EAN-13

User Preferences 4-5User PreferencesDefault ParametersThe scanner can be reset to two types of defaults: factory defaults or custom defaults. Scan the

Página 127 - Discrete 2 of 5 (DTF)

WLS 9500 Product Reference Guide4-6Beeper ToneTo select a decode beep frequency (tone), scan the Low Frequency, Medium Frequency, or High Frequency ba

Página 128 - D 2 of 5 - Any Length

User Preferences 4-7Power ModeThis parameter determines whether or not power remains on after a decode attempt. When in reduced power mode, the scanne

Página 129 - Chinese 2 of 5

WLS 9500 Product Reference Guide4-8Scan Line WidthScan a bar code below to set the scan line width. Laser On TimeThis parameter sets the maximum time

Página 130 - Codabar (NW - 7)

User Preferences 4-9Beep After Good DecodeScan a bar code below to select whether or not the scanner beeps after a good decode. If Do Not Beep After G

Página 131 - *Disable CLSI Editing

WLS 9500 Product Reference Guide4-10

Página 132 - *Disable NOTIS Editing

5Keyboard Wedge InterfaceIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 133 - *Disable MSI

WLS 9500 Product Reference Guide5-2

Página 134 - *One MSI Check Digit

Keyboard Wedge Interface 5-3IntroductionThis chapter describes how to set up a Keyboard Wedge interface with the scanner. With this interface, the sca

Página 135 - *MOD 10/MOD 10

ContentsAbout This GuideIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 136 - RSS (Reduced Space Symbology)

WLS 9500 Product Reference Guide5-49. To modify any other parameter options, scan the appropriate bar codes in this chapter.Keyboard Wedge Parameter D

Página 137 - Convert RSS to UPC/EAN

Keyboard Wedge Interface 5-5Keyboard Wedge Host ParametersKeyboard Wedge Host TypesSelect the Keyboard Wedge host by scanning one of the bar codes bel

Página 138 - Redundancy Level

WLS 9500 Product Reference Guide5-6Keyboard Wedge Country Types (Country Codes)Scan the bar code corresponding to the keyboard type. If the keyboard t

Página 139 - Redundancy Level (continued)

Keyboard Wedge Interface 5-7Ignore Unknown CharactersUnknown characters are characters the host does not recognize. When Send Bar Codes With Unknown C

Página 140 - Security Level

WLS 9500 Product Reference Guide5-8Keystroke DelayThis is the delay in milliseconds between emulated keystrokes. Scan a bar code below to increase the

Página 141 - Bi-directional Redundancy

Keyboard Wedge Interface 5-9Alternate Numeric Keypad EmulationThis allows emulation of most other country keyboard types not listed in Keyboard Wedge

Página 142 - *Normal Intercharacter Gaps

WLS 9500 Product Reference Guide5-10Convert Wedge DataWhen enabled, the scanner will convert all bar code data to the selected case.Function Key Mappi

Página 143 - Miscellaneous Scanner Options

Keyboard Wedge Interface 5-11FN1 SubstitutionWhen enabled, the scanner replaces FN1 characters in an EAN128 bar code with a keystroke chosen by the us

Página 144

WLS 9500 Product Reference Guide5-12Keyboard MapsThe following keyboard maps are provided for prefix/suffix keystroke parameters. To program the prefi

Página 145 - Errors While Scanning

Keyboard Wedge Interface 5-13ASCII Character Set for Keyboard WedgeCode 39 Full ASCII interprets the bar code special character ($ + % /) preceding a

Página 146

WLS 9500 Product Reference GuideviChapter 3. Maintenance, Troubleshooting& Technical SpecificationsIntroduction . . . . . . . . . . . . . . . . .

Página 147 - Prefix/Suffix Values

WLS 9500 Product Reference Guide5-141027 %A CTRL [ /ESC11028 %B CTRL \1029 %C CTRL ]1030 %D CTRL 61031 %E CTRL -1032 Space Space1033 /A !1034 /B “1035

Página 148 - Scan Data Transmission Format

Keyboard Wedge Interface 5-151060 %G <1061 %H =1062 %I >1063 %J ?1064 %V @1065 A A1066 B B1067 C C1068 D D1069 E E1070 F F1071 G G1072 H H1073 I

Página 149 - *Data As Is

WLS 9500 Product Reference Guide5-161093 %M ]1094 %N ^1095 %O _1096 %W ‘1097 +A a1098 +B b1099 +C c1100 +D d1101 +E e1102 +F f1103 +G g1104 +H h1105 +

Página 150 - *Disable No Read

Keyboard Wedge Interface 5-171126 %S ~Table 5-3. Keyboard Wedge ALT Key Character SetALT Keys Keystroke2065 ALT A2066 ALT B2067 ALT C2068 ALT D2069 AL

Página 151

WLS 9500 Product Reference Guide5-18Table 5-4. Keyboard Wedge GIU Key Character SetGUI Keys Keystrokes3000 Right Control Key3048 GUI 03049 GUI 13050 G

Página 152

Keyboard Wedge Interface 5-193090 GUI ZTable 5-5. Keyboard Wedge F Key Character SetF Keys Keystroke5001 F15002 F25003 F35004 F45005 F55006 F65007 F75

Página 153 - Standard Default Parameters

WLS 9500 Product Reference Guide5-206044 undefined6045 -6046 .6047 /6048 06049 16050 26051 36052 46053 56054 66055 76056 86057 96058 Enter6059 Num Loc

Página 154

Keyboard Wedge Interface 5-217016 Dn Arrow7017 Left Arrow7018 Right ArrowTable 5-7. Keyboard Wedge Extended Keypad Character Set (Continued)Extended K

Página 155

WLS 9500 Product Reference Guide5-22

Página 156

6USB InterfaceIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 157

Contents viiUSB InterfaceIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 158

WLS 9500 Product Reference Guide6-2

Página 159 - Sample Bar Codes

USB Interface 6-3IntroductionThis chapter covers the connection and setup of the scanner to a USB host. The scanner attaches directly to a USB host,

Página 160

WLS 9500 Product Reference Guide6-4To set up the scanner:Interface cables vary depending on configuration. The connectors illustrated in Figure 6-1are

Página 161 - EAN-13, 100%

USB Interface 6-5USB Host ParametersUSB Device TypeSelect the desired USB device type.When changing USB Device Types, the scanner automatically resta

Página 162 - 123456789012

WLS 9500 Product Reference Guide6-6USB Country Keyboard Types (Country Codes)Scan the bar code corresponding to the keyboard type. This setting applie

Página 163

USB Interface 6-7USB Country Keyboard Types (Country Codes continued)Italian WindowsSwedish WindowsUK English WindowsJapanese Windows (ASCII)Portugue

Página 164

WLS 9500 Product Reference Guide6-8USB Keystroke DelayThis parameter sets the delay, in milliseconds, between emulated keystrokes. Scan a bar code bel

Página 165 - Numeric Bar Codes

USB Interface 6-9USB Ignore Unknown CharactersThis option applies only to the HID Keyboard Emulation device and IBM device. Unknown characters are ch

Página 166

WLS 9500 Product Reference Guide6-10USB Keyboard FN 1 SubstitutionThis option applies only to the USB HID Keyboard Emulation device. When enabled, thi

Página 167

USB Interface 6-11Simulated Caps LockWhen enabled, the scanner will invert upper and lower case characters on the scanner bar code as if the Caps Loc

Página 168

WLS 9500 Product Reference GuideviiiCode 32 Prefix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 169 - ASCII Character Sets

WLS 9500 Product Reference Guide6-12ASCII Character Set for USBTable 6-2. ASCII Character Set for USBASCII ValueFull ASCIICode 39 Encode Character Key

Página 170

USB Interface 6-131030 %D CTRL 61031 %E CTRL -1032 Space Space1033 /A !1034 /B “1035 /C #1036 /D $1037 /E %1038 /F &1039 /G ‘1040 /H (1041 /I )10

Página 171

WLS 9500 Product Reference Guide6-141063 %J ?1064 %V @1065 A A1066 B B1067 C C1068 D D1069 E E1070 F F1071 G G1072 H H1073 I I1074 J J1075 K K1076 L L

Página 172

USB Interface 6-151096 %W `1097 +A a1098 +B b1099 +C c1100 +D d1101 +E e1102 +F f1103 +G g1104 +H h1105 +I i1106 +J j1107 +K k1108 +L l1109 +M m1110

Página 173

WLS 9500 Product Reference Guide6-16Table 6-3. USB ALT Key Character SetALT Keys Keystroke2064 ALT 22065 ALT A2066 ALT B2067 ALT C2068 ALT D2069 ALT E

Página 174

USB Interface 6-17Table 6-4. USB GUI Key Character SetGUI Key Keystroke3000 Right Control Key3048 GUI 03049 GUI 13050 GUI 23051 GUI 33052 GUI 43053 G

Página 175 - Table D-4. GUI Shift Keys

WLS 9500 Product Reference Guide6-183088 GUI X3089 GUI Y3090 GUI ZTable 6-5. USB F Key Character SetF Keys Keystroke5001 F15002 F25003 F35004 F45005 F

Página 176

USB Interface 6-19Table 6-6. USB Numeric Keypad Character SetNumeric Keypad Keystroke6042 *6043 +6044 undefined6045 -6046 .6047 /6048 06049 16050 260

Página 177

WLS 9500 Product Reference Guide6-20Table 6-7. USB Extended Keypad Character SetExtended Keypad Keystroke7001 Break7002 Delete7003 PgUp7004 End7005 Pg

Página 178

7SymbologiesIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 179

Contents ixBi-directional Redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-53Symbology - Int

Página 180

WLS 9500 Product Reference Guide7-2Enable/Disable Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 181 - Programming Reference

Symbologies 7-3Redundancy Level 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 182

WLS 9500 Product Reference Guide7-4

Página 183 - Symbol Code Identifiers

Symbologies 7-5IntroductionThis chapter describes symbology features and provides the programming bar codes for selecting these features. Before progr

Página 184 - AIM Code Identifiers

WLS 9500 Product Reference Guide7-6Symbology Parameter DefaultsTable 7-1 lists the defaults for all symbologies parameters. To change any option, scan

Página 185 - ]C1AIMID

Symbologies 7-7Code 39 Check Digit Verification Disable 7-25Transmit Code 39 Check Digit Disable 7-26Code 39 Full ASCII Conversion Disable 7-27Buffer

Página 186

WLS 9500 Product Reference Guide7-8RSS (Reduced Space Symbology)RSS 14 Disable 7-48RSS Limited Disable 7-48RSS Expanded Disable 7-48Convert RSS to UPC

Página 187

Symbologies 7-9UPC/EANEnable/Disable UPC-A/UPC-ETo enable or disable UPC-A or UPC-E, scan the appropriate bar code below. *Enable UPC-ADisable UPC-A*E

Página 188

WLS 9500 Product Reference Guide7-10Enable/Disable UPC-E1UPC-E1 is disabled by default.To enable or disable UPC-E1, scan the appropriate bar code belo

Página 189

Symbologies 7-11Enable/Disable Bookland EANTo enable or disable Bookland EAN, scan the appropriate bar code below.Decode UPC/EAN/JAN SupplementalsSupp

Comentários a estes Manuais

Sem comentários