Please Read
Note:
The Wasp CCD Scanner is ready to scan the most popular
bar codes out of the box. This manual should only be
used to make changes in the configuration of the
scanner for specific applications. This scanner does not
require software or drivers to operate. The scanner enters
data as keyboard data. Please review this manual before
scanning any of the programming bar codes in this manual.
Tech Tip
If you are unsure of the scanner configuration or have
scanned the incorrect codes, please scan the default
bar code on page 6. This will reset the scanner to its
factory settings.
CCD Programming Guide
for Wasp Bar Code CCD Scanner
Vista de página 0
1 2 3 4 5 6 ... 30 31

Resumo do Conteúdo

Página 1 - CCD Programming Guide

Please ReadNote:The Wasp CCD Scanner is ready to scan the most popularbar codes out of the box. This manual should only beused to make changes in the

Página 2

7Note: Please use Appendix B regarding the prefix string. You may add up to 4characters as a Preamble.Note: Please refer to Appendix B regarding the s

Página 3 - Table of Contents

8*DefaultBeep On/OffCCD Setup & Configuration—CCD Audio Configuration:EndBeginOn*OffScanner VolumeLowHigh*

Página 4 - Introduction

9Case SensitivityThe 'Case Sensitivity' setting provides specific options on how to pass your datato the keyboard buffer. 'Case Sensiti

Página 5 - Installation

10The 'CCD Scanning Control' configuration allows the user to customize how thet rigger is to opera t e, the length of time in which the LED

Página 6 - Quick Start

11Code 39Interleaved 2 of 5CodabarUPC-AUPC-A 2 digit add-onUPC-A 5 digit add-onUPC-E 2 digit add-onUPC-E 5 digit add-onUPC-EThe 'Enable Bar Code

Página 7 - Bar Code Symbologies

12The 'Enable Bar Code Symbologies' configuration is used to enable or disablethe various codes that the reader is able to scan. Multiple ba

Página 8

13*DefaultStandard TypeFull ASCIINoYesNoYesNoYesCode 39 is the most frequently used symbology in industrial bar code systemst o d ay and is ex t e n s

Página 9

14*DefaultNoYesNoYesI n t e rl e aved 2 of 5 is a va ri a ble length, nu m e ric bar code with an even number ofd i g i t s. It is typically used in i

Página 10 - CCD Setup & Configuration

15*DefaultCodabar is a va ri a ble length symbology capable of encoding up to 16 chara c t e r s.Codabar can encode six special alphanu m e ric chara

Página 11

16*DefaultOffOnUPC-A (Universal Product Code-A) is a fixed length symbology and is the mostcommon bar code used for retail product labeling. It is see

Página 12

© Copyright Wasp TechnologiesAll rights reserved.Version 2.0No part of this publication may be reproduced or transmitted in anyform or by any means wi

Página 13

17*Default0 and 10 onlyUPC-E (Universal Product Code-E) is also a fixed length symbology and is acompressed six digit code used for marking small pack

Página 14

18*DefaultE A N / JAN-13 (European Article Number/Japanese Article Number) is a fixe dlength symbology and is similar to the UPC-A symbology, but enco

Página 15

19*DefaultThe EAN/JAN-8 is a fixed length symbology and is similar to the UPC-E code,but includes two more digits for the country code. The nominal he

Página 16

20Code 39Interleaved 2 of 5CodabarCode 128MSI/PlesseyCCD Setup & Configuration—Bar Code Test Symbols—Appendix ANote: Make sure that the appropriat

Página 17

21UPC-AUPC-EUPC-E5 digit supplementUPC-E2 digit supplementUPC-A2 digit supplementUPC-A5 digit supplementCCD Setup & Configuration—Bar Code Test Sy

Página 18

22CCD Setup & Configuration—Bar Code Test Symbols—Appendix A (cont.)EAN/JAN 8EAN/JAN 85 digit supplementEAN/JAN 82 digit supplementEAN/JAN 13EAN/J

Página 19

Preamble/Postamble Addition Table23CCD Setup & Configuration—Preamble/Postamble Addition Table—Appendix BUse this table to add preamble and postam

Página 20

24Preamble/Postamble Addition Table (cont.)58 X59 Y5A Z5B [5C \5D ]5E ^5F _60 `61 a62 b63 c64 d65 e66 f67 g68 h69 i6A jCode ASCII Code ASCII7E ~7F Nul

Página 21

25CCD Setup & Configuration—Preamble/Postamble Addition—Appendix B (cont.)0 81 92 A3 B4 C5 D6 E7 F

Página 22

26CCD Setup & Configuration—Preamble/Postamble Addition—Special CharactersAdd ShiftAdd Right ControlAdd Left Control Add Right ALTAdd Left ALTUse

Página 23

Table of ContentsChapter 1. Introduction...1Chapter 2. Installation...

Página 24

27CCD Setup & Configuration—Additional Scanner Functions—Appendix CYour Wasp Bar Code CCD Scanner can perform additional functions, such as:1. Neg

Página 25

Wasp Technologies products are warranted against defects in workmanshipand materials for a period of one year from the date of shipment, providedthat

Página 26

1Chapter 1IntroductionBar coding is the most common Automated Data Collection (ADC) technologyproviding timely, error-free information that can be use

Página 27

2Chapter 2Installation1. Turn off your computer.2. Plug the keyboard wedge cable into the handle of the CCD reader.3. Unplug your PC keyboard cable an

Página 28

3Chapter 3Quick StartYour Wasp CCD Scanner is ready to go.The default settings of the WaspCCD Scanner have been pre-programmed for the most common bar

Página 29

4Chapter 4Bar Code SymbologiesBar codes are symbols consisting of a series of bars and spaces which can beapplied to packages, cartons, bottles, and o

Página 30

5Chapter 5CCD Setup & ConfigurationIn order to configure the Wasp CCD scanner, you must familiarize yourself withthe setup procedures on the follo

Página 31 - Product Support

6The 'Set Default' configuration restores the factory default settings.Tip: Use this option to restore the factory default settings if you a

Comentários a estes Manuais

Sem comentários